Key Features

Assembly Type DCDA
Hazard Rating Low Health Hazard
ASSE Standard ASSE 1048
Spec Sheet Download
See all product information

Similar products

Watts 3/4" Backflow Preventer LF009M3QT.34
Watts Watts 3/4" Backflow Preventer LF009M3QT.34
Sale price$738.73 Regular price$1,590.00
Watts LF007M1-QT-FZ 2
Watts LF007-QT-FZ 1/2
Compare Products

Specifications

Description

The Watts 007M1DCDA-OSY-CFM-FZ 2 is a 2" double check detector assembly (DCDA), approved for low health hazard protection. It features a bronze body and a silicone seat. Rated to 700 psi.

This 2 inch double check detector backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and water of non-potable quality from being pumped or siphoned into the potable water supply due to backsiphonage and or backpressure in accordance with national plumbing codes and water authority requirements. It is ideal for protection at cross-connections identified as non-health hazards such as on fire protection systems and from other contaminants found at the service line entrance. This compact modular design with a single access cover for easy maintenance is approved for horizontal and vertical flow up installation. It consists of a cast bronze body, outside stem and yoke resilient seated gate valves, captured spring check valves, and four test cocks. It comes with a cubic feet per minute meter to detect underground leaks and unauthorized water use. The double check valve includes a freeze sensor for use with SentryPlus Alert® technology to signal facility personnel when temperature nears and reaches the freezing point. Freeze alerts feature available with add-on connection kit for Wi-Fi networks, building management systems (BMS), irrigation management systems (IMS).

Features

  • Includes a freeze sensor for use with SentryPlus Alert technology to signal facility personnel when temperature nears and reaches the freezing point
  • Available freeze sensor connection kit to activate a monitoring system that trigger alerts for low and freezing temperatures
  • Cast bronze body construction
  • Furnished with a cubic feet per minute meter
  • Freeze alerts feature available with add-on connection kit for Wi-Fi networks, building management systems (BMS), and irrigation management systems (IMS)
  • Replaceable seats and discs
  • No special tools are required for servicing
  • Includes: Test Cocks

Common Questions

What hazard level is this DCDA approved for?
It is rated for low health hazard (non-toxic, "pollutant") cross-connections only. Where the substance downstream could be a health hazard, codes require a reduced pressure zone (RPZ) assembly instead. The assembly is listed to ASSE 1048.
Can this be installed on potable water?
No. This model is not certified lead-free, so it may not be installed in potable water systems in states enforcing the NSF/ANSI 372 weighted-average lead rule. Use it on non-potable service — fire lines, irrigation or industrial water — or order the LF (lead-free) version of this model for drinking-water use.
Does this assembly have to be tested every year?
Yes. This is a field-testable assembly. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter. It carries USC FCCCHR approval, which many jurisdictions accept as their sole approval list.
What shutoff valves are included?
It is supplied with outside screw and yoke (OS&Y) gate valves on the inlet and outlet. OS&Y gates give the visible open/shut indication that fire-line and many water-authority specs require.
Is this suitable for a fire sprinkler line?
Yes. Detector assemblies are built for fire sprinkler service: the metered bypass registers the low flows that reveal a leak or an unauthorized tap on the fire line. This model is UL Classified. The bypass meter reads in CFM.
How does this have to be installed?
It is approved for either horizontal or vertical installation, with the flow arrow on the body pointing in the direction of flow.

Specifications

  • Type: Double Check
  • Size: 2"
  • Inlet Size: 2"
  • Outlet Size: 2"
  • Body Material: Bronze
  • Seat / Seal Material: Silicone
  • Max Pressure (psi): 700
  • Application: Fire Protection
  • Backflow Protection: Both
  • Operation: Continuous
  • Country of Origin: United States
  • Warranty: 1 Year Limited
  • MPN: 007M1DCDA-OSY-CFM-FZ 2
  • Certifications: ASSE-1048, UL, USC
  • Lead-Free: No
  • Assembly Type: DCDA
  • Hazard Protection Level: Low Health Hazard
  • ASSE Standard: ASSE 1048
  • USC FCCCHR Approved: Yes
  • Fire Protection Listing: UL Classified
  • Field Testable: Yes
  • Shutoff Valves: OSY Gate
  • Approved Orientation: Horizontal & Vertical
  • Flood Sensor (SentryPlus Alert): No
  • Strainer Included: No
  • Air Gap Fitting Included: No
  • Bypass Meter: CFM

Product Information

SKUUPCCountry of OriginWarrantySpec SheetInstall Sheet
T062725 098268593778 United States 1 Year Limited DownloadDownload

Dimensions

Size Nominal 2" Inlet Size 2"
Outlet Size 2" ——

Details

Series 007M1DCDA Device Type Double Check
Body Material Bronze Seat Material Silicone
Application Fire Protection Operation Continuous
Max Pressure PSI 700.0 psi Backflow Protection Both
Options Test Cocks Min Temp °F 33.0 °F
Assembly Type DCDA Hazard Rating Low Health Hazard
ASSE Standard ASSE 1048 USC Approved Yes
Fire Listing UL Classified Testable Yes
Shutoff Valve Type OSY Gate Orientation Horizontal & Vertical
Detector Meter CFM ——

Certifications & Standards

ASSE-1048 UL
USC —

Compare with similar products

Backflow Protection
Both
Both
Both
Both
Both
Assembly Type
DCDA
DCDA
DCDA
DCDA
DCDA
Hazard Rating
Low Health Hazard
Low Health Hazard
Low Health Hazard
Low Health Hazard
Low Health Hazard
ASSE Standard
ASSE 1048
ASSE 1048
ASSE 1048
ASSE 1048
ASSE 1048
USC Approved
Yes
Yes
Yes
Yes
Yes
Fire Listing
UL Classified
UL Classified, FM Approved
UL Classified, FM Approved
UL Classified, FM Approved
UL Classified, FM Approved
Testable
Yes
Yes
Yes
Yes
Yes
Shutoff Valve Type
OSY Gate
Butterfly (Grooved)
Butterfly (Grooved)
Butterfly (Grooved)
Butterfly (Grooved)
Detector Meter
CFM
CFM
GPM
CFM
CFM
Series
007M1DCDA
757DCDA
757DCDA
757DCDA
757DCDA
Country Of Origin
United States
United States
United States
United States
United States
Warranty
1 Year Limited
1 Year Limited
1 Year Limited
1 Year Limited
1 Year Limited
Spec Sheet
Device Type
Double Check
Double Check
Double Check
Double Check
Double Check
Size Nominal
2"
3"
6"
6"
3"
Inlet Size
2"
3"
6"
6"
3"
Outlet Size
2"
3"
6"
6"
3"
Lead Free
—
Yes
Yes
Yes
Yes
End Connection
—
Grooved
Grooved
Grooved
Grooved
Body Material
Bronze
Stainless
Stainless
Stainless
Stainless
Seat Material
Silicone
Silicone
Silicone
Silicone
Silicone
Application
Fire Protection
Fire Protection
Fire Protection
Fire Protection
Fire Protection
Operation
Continuous
Continuous
Continuous
Continuous
Continuous
Max Pressure PSI
700.0 psi
175.0 psi
175.0 psi
175.0 psi
175.0 psi
Max Temp °F
—
140.0 °F
140.0 °F
140.0 °F
140.0 °F
Certifications
ASSE-1048, UL, USC
UL, FM, USC
UL, FM, USC
UL, FM, USC
UL, FM, USC
Options
Test Cocks
Test Cocks, Gear Operator, Tamper Switch
Test Cocks, Gear Operator, Tamper Switch
Test Cocks, Gear Operator, Tamper Switch
Test Cocks, Gear Operator, Tamper Switch
Min Temp °F
33.0 °F
33.0 °F
33.0 °F
33.0 °F
33.0 °F