Specifications
Description
The Zurn Wilkins 8-375A is a 8" lead-free reduced pressure zone (RPZ) backflow preventer with Flanged connections, approved for high health hazard protection. It features a ductile iron body. Rated to 175 psi and up to 140°F. This model is certified lead-free for potable-water installations.
The 375A Reduced Pressure Principle Backflow Assembly is utilized where a potential high health hazard exists and is ideal for use when lead-free valves are required protecting against both backsiphonage and backpressure of contaminated water into the potable water supply. The 375A includes a lightweight, grooved, epoxy-coated ductile iron valve body eliminating exposure to corrosion. With multiple options for NRS, OS&Y, and Butterfly shut-off valves, the 375A utilizes the Wilkins low headloss Compound Check and offers the lowest lifecycle costs on the market.
Features
- Multiple shut-off valve options for every application eases installation
- Complete epoxy coating inside and outside of valve body eliminating exposure to corrosion
- Utilizes Wilkins low headloss compound check for reliable and superior performance
- Low-lead law compliant
- ASSE® Listed 1013
- AWWA Compliant C511 (with gates only), and C550
- IAPMO® Listed
- CSA® Certified
Common Questions
- What hazard level is this RPZ approved for?
- It is rated for high health hazard (toxic) cross-connections, so it may be used on either high or low hazard service. The assembly is listed to ASSE 1013.
- Is this model legal for potable water?
- Yes. It is certified lead-free to NSF/ANSI 372, which is what state plumbing codes require for any device in a drinking-water line.
- Does this assembly have to be tested every year?
- Yes. This is a field-testable assembly with 4 test cocks. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter. It carries USC FCCCHR approval, which many jurisdictions accept as their sole approval list.
- What shutoff valves are included?
- It is supplied with non-rising stem (NRS) resilient-seated gate valves on the inlet and outlet.
- Is this listed for fire protection service?
- Yes -- it is UL Classified and C-UL Classified and FM Approved, the listings normally required for a backflow device on a fire sprinkler supply.
- Does the relief valve need a drain?
- Yes. An RPZ relief valve is designed to discharge, and it can dump a large volume of water, so it must never be installed in a pit or below grade and the discharge must be piped to an adequate drain through an air gap. The air gap fitting is not included with this model and is ordered separately. This model is connectable to a flood/discharge sensor, which signals a relief-valve discharge before it becomes a flood.
Specifications
- Type: Backflow Preventer - Reduced Pressure Principle Assembly
- Size: 8"
- Connection: Flanged
- Body Material: Ductile Iron
- Max Pressure (psi): 175
- Application: Domestic Water
- Backflow Protection: Both
- MPN: 8-375A
- Temperature: up to 140°F
- Certifications: ASSE-1013, AWWA-C511, AWWA-C606, CSA-B64.4, C-UL, UL, FM, USC, NSF-61, NSF-372, IAPMO
- Lead-Free: Yes
- Assembly Type: RPZ
- Hazard Protection Level: High Health Hazard
- ASSE Standard: ASSE 1013
- USC FCCCHR Approved: Yes
- Fire Protection Listing: UL Classified;C-UL Classified;FM Approved
- Field Testable: Yes
- Number of Test Cocks: 4
- Shutoff Valves: NRS Gate
- Flood Sensor: Yes
Dimensions
| Size Nominal | 8" | End Connection | Flanged |
Details
| Series | 375A | Device Type | Backflow Preventer - Reduced Pressure Principle Assembly |
| Lead Free | Yes | Body Material | Ductile Iron |
| Application | Domestic Water | Max Pressure PSI | 175.0 psi |
| Max Temp °F | 140.0 °F | Backflow Protection | Both |
| Assembly Type | RPZ | Hazard Rating | High Health Hazard |
| ASSE Standard | ASSE 1013 | USC Approved | Yes |
| Fire Listing | UL Classified, C-UL Classified, FM Approved | Testable | Yes |
| Test Cocks | 4 | Shutoff Valve Type | NRS Gate |
| Flood Sensor | Yes | — | — |
Certifications & Standards
| ASSE-1013 | AWWA-C511 |
| AWWA-C606 | CSA-B64.4 |
| C-UL | UL |
| FM | USC |
| NSF-61 | NSF-372 |
| IAPMO | — |
Compare with similar products
| Backflow Protection | Both
| Both
|
| Assembly Type | RPZ
| RPZ
|
| Hazard Rating | High Health Hazard
| High Health Hazard
|
| ASSE Standard | ASSE 1013
| ASSE 1013
|
| USC Approved | Yes | Yes |
| Fire Listing | UL Classified, C-UL Classified, FM Approved
| UL Classified, C-UL Classified
|
| Testable | Yes | Yes |
| Test Cocks | 4
| 4
|
| Shutoff Valve Type | NRS Gate
| Quarter-Turn Ball
|
| Series | 375A
| 112-975XL2
|
| Spec Sheet | ||
| Install Sheet | ||
| Device Type | Backflow Preventer - Reduced Pressure Principle Assembly
| Backflow Preventer - Bronze Reduced Pressure Principle Assembly
|
| Size Nominal | 8"
| 1-1/2"
|
| Lead Free | Yes | Yes |
| End Connection | Flanged
| FNPT
|
| Body Material | Ductile Iron
| Bronze
|
| Application | Domestic Water
| Domestic Water
|
| Max Pressure PSI | 175.0 psi | 175.0 psi |
| Max Temp °F | 140.0 °F | 180.0 °F |
| Certifications | ASSE-1013, AWWA-C511, AWWA-C606, CSA-B64.4, C-UL, UL, FM, USC, NSF-61, NSF-372, IAPMO
| ASSE-1013, AWWA-C511, CSA-B64.4, C-UL, UL, USC, NSF-61, NSF-372, IAPMO
|
Recommended Products
Recently Viewed
What Our Customers Say
-
Got me flushing again
-
Needed a faucet quick. They had what we needed within 5 minutes and were all so nice
-
Excellent service as always. All the stuff I needed. Thanks Julio.
-
absolutely the most helpful gracious and polite people I have dealt with in a very long time. thank you so much!!
-
Material Always on Hand or Quick order
-
Excellent service and help from the staff who work at this place
-
Excellent service and attention, everyone was very friendly. 5 stars for Mr. Julio.
-
Excellent service at the counter. Manuel and Ray are super knowledgeable and helpful. Thank you!
-
Excellent service, very friendly,
Julio and his coworkers 💯💯💯 -
Good service
-
Professional services, excellent customer service
-
No nonsense great customer service 👍