Specifications
Description
The Zurn Wilkins 8-350ADA is a 8" lead-free double check detector assembly (DCDA) with Flanged connections, approved for low health hazard protection. It features a ductile iron body. Rated to 175 psi and up to 140°F. This model is certified lead-free for potable-water installations.
The 350ADA Double Check Detector Backflow Preventer protects against both backsiphonage and backpressure in low health hazard, fire protection applications. Featuring a metered bypass system, the 350ADA efficiently detects leaks and any unauthorized water use. Its single access cover reduces downtime and added costs associated with maintenance and repairs. Lighter in weight than the 350DA Model, the 350ADA features a short lay-length for compact, versatile installation in horizontal or vertical positions, and is available in a variety of flanged, grooved, or grooved x flanged end connections.
Features
- Horizontal or vertical installation offers versatility and reduces installation time
- Leak and unauthorized water use detection decreases costs over time
- Patented Compound Check offers reliable performance and improved flow characteristics
- Lack of threads or taps in cover and body reduces corrosion exposure
- ASSE® Listed 1048
- AWWA Compliant C510 (with gates only), and C550
- CSA® Certified B64.5
- UL® Classified
Common Questions
- What hazard level is this DCDA approved for?
- It is rated for low health hazard (non-toxic, "pollutant") cross-connections only. Where the downstream substance could be a health hazard, codes require a reduced pressure zone (RPZ) assembly or a detector assembly instead. The assembly is listed to ASSE 1048.
- Is this model legal for potable water?
- Yes. It is certified lead-free to NSF/ANSI 372, which is what state plumbing codes require for any device in a drinking-water line.
- Does this assembly have to be tested every year?
- Yes. This is a field-testable assembly. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter. It carries USC FCCCHR approval, which many jurisdictions accept as their sole approval list.
- What shutoff valves are included?
- It is supplied with non-rising stem (NRS) resilient-seated gate valves on the inlet and outlet.
- Is this suitable for a fire sprinkler line?
- Yes. Detector assemblies are built for fire sprinkler service: the metered bypass registers the low flows that reveal a leak or an unauthorized tap on the fire line. This model is UL Classified and C-UL Classified and FM Approved. The bypass meter reads in GPM.
- How does this have to be installed?
- It is approved for either horizontal or vertical installation, with the flow arrow on the body pointing in the direction of flow.
Specifications
- Type: Backflow Preventer - Double Check Detector Assembly
- Size: 8"
- Connection: Flanged
- Body Material: Ductile Iron
- Max Pressure (psi): 175
- Application: Fire Protection
- Backflow Protection: Both
- MPN: 8-350ADA
- Temperature: up to 140°F
- Certifications: ASSE-1048, AWWA-C510, AWWA-C606, CSA-B64.5, C-UL, UL, FM, USC, NSF-61, NSF-372
- Lead-Free: Yes
- Assembly Type: DCDA
- Hazard Protection Level: Low Health Hazard
- ASSE Standard: ASSE 1048
- USC FCCCHR Approved: Yes
- Fire Protection Listing: UL Classified;C-UL Classified;FM Approved
- Field Testable: Yes
- Shutoff Valves: NRS Gate
- Approved Orientation: Horizontal & Vertical
- Bypass Meter: GPM
Dimensions
| Size Nominal | 8" | End Connection | Flanged |
Details
| Series | 350ADA | Device Type | Backflow Preventer - Double Check Detector Assembly |
| Lead Free | Yes | Body Material | Ductile Iron |
| Application | Fire Protection | Max Pressure PSI | 175.0 psi |
| Max Temp °F | 140.0 °F | Backflow Protection | Both |
| Assembly Type | DCDA | Hazard Rating | Low Health Hazard |
| ASSE Standard | ASSE 1048 | USC Approved | Yes |
| Fire Listing | UL Classified, C-UL Classified, FM Approved | Testable | Yes |
| Shutoff Valve Type | NRS Gate | Orientation | Horizontal & Vertical |
| Detector Meter | GPM | — | — |
Certifications & Standards
| ASSE-1048 | AWWA-C510 |
| AWWA-C606 | CSA-B64.5 |
| C-UL | UL |
| FM | USC |
| NSF-61 | NSF-372 |
Recommended Products
Recently Viewed
What Our Customers Say
-
Excellent service, very friendly,
Julio and his coworkers 💯💯💯 -
Material Always on Hand or Quick order
-
Got me flushing again
-
A beautiful and smart woman with a helpful heart that is a surprise to find in a plumbing supply co., Nekell.
-
I recommend them to everyone, they have EVERYTHING, great customer service and always come through for our day to day needs.
-
These guys are pros and have everything you could need!
-
No nonsense great customer service 👍
-
Excellent service at the counter. Manuel and Ray are super knowledgeable and helpful. Thank you!
-
absolutely the most helpful gracious and polite people I have dealt with in a very long time. thank you so much!!
-
Excellent
-
The best
Is ray -
They had what I needed to replace the stem on my 60 year old bathroom showers. Great service.