Specifications
Description
The Zurn Wilkins 6-350ASTDAR-A is a 6" lead-free double check detector assembly (DCDA) with Flanged connections, approved for low health hazard protection. It features a stainless body. This model is certified lead-free for potable-water installations.
The patented 350ASTDAR Replacement Double Check Detector Assembly with stainless steel body is a custom length assembly for drop-in replacement of an assembly that cannot be repaired. The AR series drastically reduces installation and system down time.
Features
- Designed to replace old, long lay length Double Check Detector Assemblies
- 304L Grade stainless steel body and spool
- Reduced the cost of assembly replacement
- ASSE® Listed, AWWA Compliant and CSA® Certified
- UL® Classified and C-UL® Classified
- Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
Common Questions
- What hazard level is this DCDA approved for?
- It is rated for low health hazard (non-toxic, "pollutant") cross-connections only. Where the downstream substance could be a health hazard, codes require a reduced pressure zone (RPZ) assembly or a detector assembly instead.
- Is this model legal for potable water?
- Yes. It is certified lead-free to NSF/ANSI 372, which is what state plumbing codes require for any device in a drinking-water line.
- Does this assembly have to be tested every year?
- Yes. This is a field-testable assembly. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter. It carries USC FCCCHR approval, which many jurisdictions accept as their sole approval list.
- What shutoff valves are included?
- It is supplied with non-rising stem (NRS) resilient-seated gate valves on the inlet and outlet.
- Is this suitable for a fire sprinkler line?
- Yes. Detector assemblies are built for fire sprinkler service: the metered bypass registers the low flows that reveal a leak or an unauthorized tap on the fire line. This model is UL Classified and C-UL Classified. The bypass meter reads in GPM.
Specifications
- Type: Replacement Double Check Detector Assembly
- Size: 6"
- Connection: Flanged
- Body Material: Stainless
- Application: Fire Protection
- Backflow Protection: Both
- MPN: 6-350ASTDAR-A
- Certifications: CSA, C-UL, UL, USC, NSF-372
- Lead-Free: Yes
- Assembly Type: DCDA
- Hazard Protection Level: Low Health Hazard
- USC FCCCHR Approved: Yes
- Fire Protection Listing: UL Classified;C-UL Classified
- Field Testable: Yes
- Shutoff Valves: NRS Gate
- Bypass Meter: GPM
Dimensions
| Size Nominal | 6" | End Connection | Flanged |
Details
| Series | 350ASTDAR | Device Type | Replacement Double Check Detector Assembly |
| Lead Free | Yes | Body Material | Stainless |
| Application | Fire Protection | Backflow Protection | Both |
| Assembly Type | DCDA | Hazard Rating | Low Health Hazard |
| USC Approved | Yes | Fire Listing | UL Classified, C-UL Classified |
| Testable | Yes | Shutoff Valve Type | NRS Gate |
| Detector Meter | GPM | — | — |
Certifications & Standards
| CSA | C-UL |
| UL | USC |
| NSF-372 | — |
Compare with similar products
| Backflow Protection | Both
| Both
| Both
| Both
| Both
| Both
|
| Assembly Type | DCDA
| RPDA
| RPDA
| RPDA
| RPDA
| RPDA
|
| Hazard Rating | Low Health Hazard
| High Health Hazard
| High Health Hazard
| High Health Hazard
| High Health Hazard
| High Health Hazard
|
| ASSE Standard | — | ASSE 1047
| ASSE 1047
| ASSE 1047
| ASSE 1047
| ASSE 1047
|
| USC Approved | Yes | Yes | Yes | Yes | Yes | Yes |
| Fire Listing | UL Classified, C-UL Classified
| UL Classified, C-UL Classified, FM Approved
| UL Classified, C-UL Classified, FM Approved
| UL Classified, C-UL Classified, FM Approved
| UL Classified, C-UL Classified, FM Approved
| UL Classified, C-UL Classified, FM Approved
|
| Testable | Yes | Yes | Yes | Yes | Yes | Yes |
| Shutoff Valve Type | NRS Gate
| NRS Gate
| NRS Gate
| NRS Gate
| NRS Gate
| NRS Gate
|
| Detector Meter | GPM
| GPM
| GPM
| GPM
| GPM
| GPM
|
| Series | 350ASTDAR
| 475STDA
| 475STDA
| 475STDA
| 475STDA
| 475DAV
|
| Spec Sheet | ||||||
| Install Sheet | ||||||
| Device Type | Replacement Double Check Detector Assembly
| Reduced Pressure Detector Assembly
| Reduced Pressure Detector Assembly
| Reduced Pressure Detector Assembly
| Reduced Pressure Detector Assembly
| Backflow Preventer - Z-Pattern (Vertical) Reduced Pressure Principle Detector Assembly -
|
| Size Nominal | 6"
| 8"
| 10"
| 4"
| 6"
| 4"
|
| Lead Free | Yes | Yes | Yes | Yes | Yes | Yes |
| End Connection | Flanged
| Flanged
| Flanged
| Flanged
| Flanged
| Flanged
|
| Body Material | Stainless
| Stainless
| Stainless
| Stainless
| Stainless
| Ductile Iron
|
| Application | Fire Protection
| Fire Protection
| Fire Protection
| Fire Protection
| Fire Protection
| Fire Protection
|
| Max Pressure PSI | — | 175.0 psi | 175.0 psi | 175.0 psi | 175.0 psi | 175.0 psi |
| Certifications | CSA, C-UL, UL, USC, NSF-372
| ASSE-1047, AWWA-C550, AWWA-C606, CSA-B64.4, C-UL, UL, FM, USC, NSF-61, NSF-372
| ASSE-1047, AWWA-C550, AWWA-C606, CSA-B64.4, C-UL, UL, FM, USC, NSF-61, NSF-372
| ASSE-1047, AWWA-C550, AWWA-C606, CSA-B64.4, C-UL, UL, FM, USC, NSF-61, NSF-372
| ASSE-1047, AWWA-C550, AWWA-C606, CSA-B64.4, C-UL, UL, FM, USC, NSF-61, NSF-372
| ASSE-1047, AWWA-C550, AWWA-C606, C-UL, UL, FM, USC, NSF-61, NSF-372
|
Recommended Products
Recently Viewed
What Our Customers Say
-
A beautiful and smart woman with a helpful heart that is a surprise to find in a plumbing supply co., Nekell.
-
I ordered online and it arrived in excellent condition and on time.
-
Good service
-
Excellent service as always. All the stuff I needed. Thanks Julio.
-
The best
Is ray -
These guys are pros and have everything you could need!
-
Excellent service, very friendly,
Julio and his coworkers 💯💯💯 -
Needed a faucet quick. They had what we needed within 5 minutes and were all so nice
-
Great place for plumbing parts and great service
-
Ray is handsome and helpful. A good man to work with for any plumbing needs.
-
Excellent service at the counter. Manuel and Ray are super knowledgeable and helpful. Thank you!
-
Got me flushing again