Specifications
Description
The Zurn Wilkins 34-710 is a 3/4" pressure vacuum breaker with FNPT connections, approved for high health hazard protection. It features a bronze body. Rated to 150 psi and up to 140°F.
The 710 Pressure Vacuum Breaker Assembly protects against backsiphonage of contaminated water into the potable water supply where a potential high health hazard exists. With fewer parts and a lightweight, compact body, the Wilkins 710 Pressure Vacuum Breaker Assembly is a low-maintenance, cost-effective solution for high-hazard irrigation applications – commercial or residential. It also features a maximum pressure of 150 psi and a temperature range of 33°F to 140°F. The 710 is available in 3/4" and 1" sizes and is more compact than any competitor valve in the marketplace. Bring effortless performance to any residential and commercial irrigation systems.
Features
- Economical and durable with a lightweight, compact body
- Compact size is ideal for space limited applications
- Corrosion resistant valve and stainless steel shutoff handles for durability
- Protects against backsiphonage where a potential high health hazard exists.
- cUPC listed; ASSE® Listed 1020
- Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
- Universal low-cost repair kits work in both 3/4 in. and 1 in. assemblies
Common Questions
- What hazard level is this PVB approved for?
- It is rated for high health hazard (toxic) cross-connections, but only against backsiphonage. The assembly is listed to ASSE 1020.
- Does this assembly have to be tested every year?
- Yes. This is a field-testable assembly. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter. It carries USC FCCCHR approval, which many jurisdictions accept as their sole approval list.
- Will this protect against backpressure?
- No. A pressure vacuum breaker protects against backsiphonage only. It will not stop backflow caused by backpressure -- a downstream pump, elevated piping or a boiler -- which requires a double check or RPZ assembly instead.
- How does this have to be installed?
- It must be installed vertically (upright), above the highest downstream outlet, per its installation instructions and ASSE listing.
Specifications
- Type: Pressure Vacuum Breaker Assembly (3/4" & 1")
- Size: 3/4"
- Connection: FNPT
- Body Material: Bronze
- Max Pressure (psi): 150
- Application: Irrigation
- Backflow Protection: Backsiphonage
- MPN: 34-710
- Temperature: up to 140°F
- Certifications: ASSE-1020, USC, IAPMO
- Assembly Type: PVB
- Hazard Protection Level: High Health Hazard
- ASSE Standard: ASSE 1020
- USC FCCCHR Approved: Yes
- Field Testable: Yes
- Approved Orientation: Vertical
Dimensions
| Size Nominal | 3/4" | End Connection | FNPT |
Details
| Series | 710 | Device Type | Pressure Vacuum Breaker Assembly (3/4" & 1") |
| Body Material | Bronze | Application | Irrigation |
| Max Pressure PSI | 150.0 psi | Max Temp °F | 140.0 °F |
| Backflow Protection | Backsiphonage | Assembly Type | PVB |
| Hazard Rating | High Health Hazard | ASSE Standard | ASSE 1020 |
| USC Approved | Yes | Testable | Yes |
| Orientation | Vertical | — | — |
Certifications & Standards
| ASSE-1020 | USC |
| IAPMO | — |
Recommended Products
Recently Viewed
What Our Customers Say
-
Julio was very helpful and knowledgeable
-
Excellent
-
Great customer service part was already waiting for me at the counter!!!! it don’t get no better than that!!
-
Excellent service
-
No nonsense great customer service 👍
-
Ray Rhodes thanks for your help. 5 star service at City Supply.
-
Professional services, excellent customer service
-
A beautiful and smart woman with a helpful heart that is a surprise to find in a plumbing supply co., Nekell.
-
Good service
-
The best
Is ray -
Excellent service, very friendly,
Julio and his coworkers 💯💯💯 -
Great place for plumbing parts and great service