Specifications
Description
The Zurn Wilkins 112-975XL3S is a 1-1/2" lead-free reduced pressure zone (RPZ) backflow preventer with FNPT connections, approved for high health hazard protection. It features a bronze body. This model is certified lead-free for potable-water installations.
The Wilkins 975XL3 Reduced Pressure Principle Backflow Assembly provides high hazard protection against backsiphonage and backpressure in potable water applications. The 975XL3 series offers the most compact and lightest bronze small backflow available on the market today. The design combines the robust time-tested construction of our 975XL/XL2 series with the innovative modular check EZSwap® design of our 375 series allowing for ease of repair and greater labor savings compared to all other brands.
Features
- Compact and shortest bronze small backflow valve on the market allowing for installation versatility
- All-bronze body ensures durability against the elements, with a Noryl®* check body and stainless-steel fasteners to resist corrosion over time.
- EZSWAP® modular check with top access speeds up repairs and replacements
- Test ports located on valve’s centerline make install and testing easy
- Interlocking connected checks provide ¼ turn to access and disassemble.
- Low-cost repair kits extend the lifespan at a significantly lower cost
- Lead Free* (0.25% max. weighted average lead content)
- ASSE Listed, UPC® Listed, Meets NSF/ANSI/CAN 61 & 372 requirements; Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California; Safe Drinking Water Act Compliant
Common Questions
- What hazard level is this RPZ approved for?
- It is rated for high health hazard (toxic) cross-connections, so it may be used on either high or low hazard service.
- Is this model legal for potable water?
- Yes. It is certified lead-free to NSF/ANSI 372, which is what state plumbing codes require for any device in a drinking-water line.
- Does this assembly have to be tested every year?
- Yes. This is a field-testable assembly with 4 test cocks. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter. It carries USC FCCCHR approval, which many jurisdictions accept as their sole approval list.
- What shutoff valves are included?
- It is supplied with quarter-turn ball valves on the inlet and outlet.
- Does the relief valve need a drain?
- Yes. An RPZ relief valve is designed to discharge, and it can dump a large volume of water, so it must never be installed in a pit or below grade and the discharge must be piped to an adequate drain through an air gap. The air gap fitting is not included with this model and is ordered separately.
Specifications
- Type: Backflow Preventer - Bronze Reduced Pressure Principle Assembly with EZ Swap Modular Check Valves
- Size: 1-1/2"
- Connection: FNPT
- Body Material: Bronze
- Application: Domestic Water
- Backflow Protection: Both
- MPN: 112-975XL3S
- Certifications: USC, NSF-61, NSF-372, IAPMO
- Lead-Free: Yes
- Assembly Type: RPZ
- Hazard Protection Level: High Health Hazard
- USC FCCCHR Approved: Yes
- Field Testable: Yes
- Number of Test Cocks: 4
- Shutoff Valves: Quarter-Turn Ball
- Strainer Included: Yes
Dimensions
| Size Nominal | 1-1/2" | End Connection | FNPT |
Details
| Series | 975XL3 | Device Type | Backflow Preventer - Bronze Reduced Pressure Principle Assembly with EZ Swap Modular Check Valves |
| Lead Free | Yes | Body Material | Bronze |
| Application | Domestic Water | Backflow Protection | Both |
| Assembly Type | RPZ | Hazard Rating | High Health Hazard |
| USC Approved | Yes | Testable | Yes |
| Test Cocks | 4 | Shutoff Valve Type | Quarter-Turn Ball |
| Strainer Included | Yes | — | — |
Certifications & Standards
| USC | NSF-61 |
| NSF-372 | IAPMO |
Compare with similar products
| Backflow Protection | Both
| Both
|
| Assembly Type | RPZ
| RPZ
|
| Hazard Rating | High Health Hazard
| High Health Hazard
|
| USC Approved | Yes | Yes |
| Testable | Yes | Yes |
| Test Cocks | 4
| 4
|
| Shutoff Valve Type | Quarter-Turn Ball
| Quarter-Turn Ball
|
| Series | 975XL3
| 112-975XL2
|
| Spec Sheet | ||
| Install Sheet | ||
| Device Type | Backflow Preventer - Bronze Reduced Pressure Principle Assembly with EZ Swap Modular Check Valves
| Backflow Preventer - Bronze Reduced Pressure Principle Assembly
|
| Size Nominal | 1-1/2"
| 1-1/2"
|
| Lead Free | Yes | Yes |
| End Connection | FNPT
| FNPT
|
| Body Material | Bronze
| Bronze
|
| Application | Domestic Water
| Domestic Water
|
| Certifications | USC, NSF-61, NSF-372, IAPMO
| ASSE-1013, AWWA-C511, CSA-B64.4, C-UL, UL, USC, NSF-61, NSF-372, IAPMO
|
Recommended Products
Recently Viewed
What Our Customers Say
-
Excellent service, very friendly,
Julio and his coworkers 💯💯💯 -
These guys are pros and have everything you could need!
-
The best
Is ray -
Excellent service as always. All the stuff I needed. Thanks Julio.
-
Good service
-
I ordered online and it arrived in excellent condition and on time.
-
A beautiful and smart woman with a helpful heart that is a surprise to find in a plumbing supply co., Nekell.
-
absolutely the most helpful gracious and polite people I have dealt with in a very long time. thank you so much!!
-
Professional services, excellent customer service
-
Great prices and customer service!
-
Ray Rhodes thanks for your help. 5 star service at City Supply.
-
Material Always on Hand or Quick order