Zurn 112-375XLS 1-1/2" Lead-Free Backflow Preventer - Reduced Pressure Principle, Flanged

SKU: 112-375XLS
Price:
Sale price$1,991.99
Stock:

Not in regular stock. We order it, inspect it and ship it to you. Delivery times may vary.

Subtotal: $1,991.99

Free shipping over $200

Key Features

Assembly Type RPZ
Hazard Rating High Health Hazard
ASSE Standard ASSE 1013
Spec Sheet Download
See all product information

Similar products

Watts 3/4" Backflow Preventer LF009M3QT.34
Watts Watts 3/4" Backflow Preventer LF009M3QT.34
Sale price$738.73 Regular price$1,590.00
Watts LF007M1-QT-FZ 2
Watts LF007-QT-FZ 1/2
Compare Products

Specifications

Description

The Zurn Wilkins 112-375XLS is a 1-1/2" lead-free reduced pressure zone (RPZ) backflow preventer with Flanged connections, approved for high health hazard protection. It is rated to 175 psi and up to 180°F. This model is certified lead-free for potable-water installations.

The Wilkins 375XL Reduced Pressure Principle Backflow Preventer provides high hazard protection for potable water applications. The EZSwap™ Pressure Vessel is removed and replaced with the Flush Fitting Tool for faster flushing and testing.

Features

  • 375XL (1/2"-2")
  • EZSwap pressure vessel is removable for easy access and added convenience
  • Durable, UV-resistant EZSwap Pressure Vessel resists corrosion and mineral build-up to better withstand harsh conditions
  • Minimal bronze construction acts as theft deterrent
  • Optional line flush tool provides easy line flushing, saving up to 15 minutes per installation and easier winterization.
  • ASSE listed 1013 and cUPC listed
  • CSA certified B64.4 and Meets the requirements of NSF/ANSI/CAN 61
  • Safe Drinking Water Act compliant
  • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California

Common Questions

What hazard level is this RPZ approved for?
It is rated for high health hazard (toxic) cross-connections, so it may be used on either high or low hazard service. The assembly is listed to ASSE 1013.
Is this model legal for potable water?
Yes. It is certified lead-free to NSF/ANSI 372, which is what state plumbing codes require for any device in a drinking-water line.
Does this assembly have to be tested every year?
Yes. This is a field-testable assembly with 4 test cocks. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter. It carries USC FCCCHR approval, which many jurisdictions accept as their sole approval list.
What shutoff valves are included?
It is supplied with non-rising stem (NRS) resilient-seated gate valves on the inlet and outlet.
Does the relief valve need a drain?
Yes. An RPZ relief valve is designed to discharge, and it can dump a large volume of water, so it must never be installed in a pit or below grade and the discharge must be piped to an adequate drain through an air gap. The air gap fitting is not included with this model and is ordered separately.

Specifications

  • Type: Backflow Preventer - Reduced Pressure Principle
  • Size: 1-1/2"
  • Connection: Flanged
  • Max Pressure (psi): 175
  • Application: Domestic Water
  • Backflow Protection: Both
  • MPN: 112-375XLS
  • Temperature: up to 180°F
  • Certifications: ASSE-1013, AWWA-C511, CSA-B64.4, USC, NSF-61, NSF-372, IAPMO
  • Lead-Free: Yes
  • Assembly Type: RPZ
  • Hazard Protection Level: High Health Hazard
  • ASSE Standard: ASSE 1013
  • USC FCCCHR Approved: Yes
  • Field Testable: Yes
  • Number of Test Cocks: 4
  • Shutoff Valves: NRS Gate

Product Information

SKUUPCSpec SheetInstall Sheet
112-375XLS 612052078489 DownloadDownload

Dimensions

Size Nominal 1-1/2" End Connection Flanged

Details

Series 1-375XLS Device Type Backflow Preventer - Reduced Pressure Principle
Lead Free Yes Application Domestic Water
Max Pressure PSI 175.0 psi Max Temp °F 180.0 °F
Backflow Protection Both Assembly Type RPZ
Hazard Rating High Health Hazard ASSE Standard ASSE 1013
USC Approved Yes Testable Yes
Test Cocks 4 Shutoff Valve Type NRS Gate

Certifications & Standards

ASSE-1013 AWWA-C511
CSA-B64.4 USC
NSF-61 NSF-372
IAPMO —

Compare with similar products

Backflow Protection
Both
Both
Assembly Type
RPZ
RPZ
Hazard Rating
High Health Hazard
High Health Hazard
ASSE Standard
ASSE 1013
ASSE 1013
USC Approved
Yes
Yes
Testable
Yes
Yes
Test Cocks
4
4
Shutoff Valve Type
NRS Gate
Quarter-Turn Ball
Series
1-375XLS
112-975XL2
Spec Sheet
Install Sheet
Device Type
Backflow Preventer - Reduced Pressure Principle
Backflow Preventer - Bronze Reduced Pressure Principle Assembly
Size Nominal
1-1/2"
1-1/2"
Lead Free
Yes
Yes
End Connection
Flanged
FNPT
Application
Domestic Water
Domestic Water
Max Pressure PSI
175.0 psi
175.0 psi
Max Temp °F
180.0 °F
180.0 °F
Certifications
ASSE-1013, AWWA-C511, CSA-B64.4, USC, NSF-61, NSF-372, IAPMO
ASSE-1013, AWWA-C511, CSA-B64.4, C-UL, UL, USC, NSF-61, NSF-372, IAPMO

Recommended Products

Recently Viewed

What Our Customers Say