Key Features

Assembly Type RPZ
Hazard Rating High Health Hazard
ASSE Standard ASSE 1013
Spec Sheet Download
See all product information

Similar products

Watts 3/4" Backflow Preventer LF009M3QT.34
Watts Watts 3/4" Backflow Preventer LF009M3QT.34
Sale price$738.73 Regular price$1,590.00
Watts LF007M1-QT-FZ 2
Watts LF007-QT-FZ 1/2
Compare Products

Specifications

Description

The Zurn Wilkins 10-375ASTOSY is a 10" lead-free reduced pressure zone (RPZ) backflow preventer with Flanged connections, approved for high health hazard protection. It features a stainless body. Rated to 175 psi and up to 140°F. This model is certified lead-free for potable-water installations.

The 375AST Reduced Pressure Principle Backflow Assembly is utilized in high hazard applications for all applications and market segments, protecting against backsiphonage and backpressure of contaminated water into the potable water supply. The 375AST offers lightweight design with a high quality, 304L grade stainless steel valve body and sensing line, plus stainless steel internals, fasteners, and springs. Multiple options for end connections, such as NRS, OS&Y, and Butterfly shut-off valves, offer supreme installation versatility, and its corrosion-resistant design saves you money on maintenance costs.

Features

  • Flanged, grooved, or grooved x flanged end connections provide versatile installation
  • Short lay-length offers reduces installation time and costs in compact spaces
  • Patented Compound Check offers reliable performance, improved flow characteristics, and installation in lower-pressure systems
  • Stainless steel body protects against corrosion
  • ASSE® Listed 1013
  • AWWA Compliant C511 (with gates only), and C550
  • UL® and C-UL® Classified

Common Questions

What hazard level is this RPZ approved for?
It is rated for high health hazard (toxic) cross-connections, so it may be used on either high or low hazard service. The assembly is listed to ASSE 1013.
Is this model legal for potable water?
Yes. It is certified lead-free to NSF/ANSI 372, which is what state plumbing codes require for any device in a drinking-water line.
Does this assembly have to be tested every year?
Yes. This is a field-testable assembly with 4 test cocks. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter. It carries USC FCCCHR approval, which many jurisdictions accept as their sole approval list.
What shutoff valves are included?
It is supplied with outside screw and yoke (OS&Y) gate valves on the inlet and outlet. OS&Y gates give the visible open/shut indication that fire-line and many water-authority specs require.
Is this listed for fire protection service?
Yes -- it is UL Classified and C-UL Classified and FM Approved, the listings normally required for a backflow device on a fire sprinkler supply.
Does the relief valve need a drain?
Yes. An RPZ relief valve is designed to discharge, and it can dump a large volume of water, so it must never be installed in a pit or below grade and the discharge must be piped to an adequate drain through an air gap. The air gap fitting is not included with this model and is ordered separately. This model is connectable to a flood/discharge sensor, which signals a relief-valve discharge before it becomes a flood.

Specifications

  • Type: Backflow Preventer - Stainless Steel Reduced Pressure Principle Assembly
  • Size: 10"
  • Connection: Flanged
  • Body Material: Stainless
  • Max Pressure (psi): 175
  • Application: Domestic Water
  • Backflow Protection: Both
  • MPN: 10-375ASTOSY
  • Temperature: up to 140°F
  • Certifications: ASSE-1013, AWWA-C511, AWWA-C606, CSA-B64.4, C-UL, UL, FM, USC, NSF-61, NSF-372, IAPMO
  • Lead-Free: Yes
  • Assembly Type: RPZ
  • Hazard Protection Level: High Health Hazard
  • ASSE Standard: ASSE 1013
  • USC FCCCHR Approved: Yes
  • Fire Protection Listing: UL Classified;C-UL Classified;FM Approved
  • Field Testable: Yes
  • Number of Test Cocks: 4
  • Shutoff Valves: OSY Gate
  • Flood Sensor: Yes

Product Information

SKUUPCSpec SheetInstall Sheet
10-375ASTOSY 612052201016 DownloadDownload

Dimensions

Size Nominal 10" End Connection Flanged

Details

Series 10-375ASTOSY Device Type Backflow Preventer - Stainless Steel Reduced Pressure Principle Assembly
Lead Free Yes Body Material Stainless
Application Domestic Water Max Pressure PSI 175.0 psi
Max Temp °F 140.0 °F Backflow Protection Both
Assembly Type RPZ Hazard Rating High Health Hazard
ASSE Standard ASSE 1013 USC Approved Yes
Fire Listing UL Classified, C-UL Classified, FM Approved Testable Yes
Test Cocks 4 Shutoff Valve Type OSY Gate
Flood Sensor Yes ——

Certifications & Standards

ASSE-1013 AWWA-C511
AWWA-C606 CSA-B64.4
C-UL UL
FM USC
NSF-61 NSF-372
IAPMO —

Compare with similar products

Backflow Protection
Both
Both
Assembly Type
RPZ
RPZ
Hazard Rating
High Health Hazard
High Health Hazard
ASSE Standard
ASSE 1013
ASSE 1013
USC Approved
Yes
Yes
Fire Listing
UL Classified, C-UL Classified, FM Approved
UL Classified, C-UL Classified
Testable
Yes
Yes
Test Cocks
4
4
Shutoff Valve Type
OSY Gate
Quarter-Turn Ball
Series
10-375ASTOSY
112-975XL2
Spec Sheet
Install Sheet
Device Type
Backflow Preventer - Stainless Steel Reduced Pressure Principle Assembly
Backflow Preventer - Bronze Reduced Pressure Principle Assembly
Size Nominal
10"
1-1/2"
Lead Free
Yes
Yes
End Connection
Flanged
FNPT
Body Material
Stainless
Bronze
Application
Domestic Water
Domestic Water
Max Pressure PSI
175.0 psi
175.0 psi
Max Temp °F
140.0 °F
180.0 °F
Certifications
ASSE-1013, AWWA-C511, AWWA-C606, CSA-B64.4, C-UL, UL, FM, USC, NSF-61, NSF-372, IAPMO
ASSE-1013, AWWA-C511, CSA-B64.4, C-UL, UL, USC, NSF-61, NSF-372, IAPMO