Specifications
Description
The Zurn Wilkins 10-350DACFM is a 10" lead-free double check detector assembly (DCDA) with Flanged connections, approved for low health hazard protection. This model is certified lead-free for potable-water installations.
The 350DA Double Check Detector Backflow Assembly protects against backsiphonage and backpressure in low health hazard, fire protection applications. Featuring a metered bypass system, the 350DA efficiently and effectively detects leaks and any unauthorized water use, saving you added costs associated with maintenance and repairs. The Wilkins Compound Check provides low headloss, and backflow installation is approved in both horizontal and vertical positions.
Features
- Horizontal or vertical installation offers versatility and eases installation
- Lowest lifecycle costs in the Backflow industry
- Patented Compound Check offers reliable performance and improved flow characteristics
- Leak and unauthorized water use detection decreases risk of damage and unnecessary costs
- ASSE® Listed 1048
- CSA® Certified B64.5
- AWWA Compliant C510
- UL® Classified
Common Questions
- What hazard level is this DCDA approved for?
- It is rated for low health hazard (non-toxic, "pollutant") cross-connections only. Where the downstream substance could be a health hazard, codes require a reduced pressure zone (RPZ) assembly or a detector assembly instead. The assembly is listed to ASSE 1048.
- Is this model legal for potable water?
- Yes. It is certified lead-free to NSF/ANSI 372, which is what state plumbing codes require for any device in a drinking-water line.
- Does this assembly have to be tested every year?
- Yes. This is a field-testable assembly. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter.
- What shutoff valves are included?
- It is supplied with non-rising stem (NRS) resilient-seated gate valves on the inlet and outlet.
- Is this suitable for a fire sprinkler line?
- Yes. Detector assemblies are built for fire sprinkler service: the metered bypass registers the low flows that reveal a leak or an unauthorized tap on the fire line. This model is UL Classified. The bypass meter reads in CFM.
- How does this have to be installed?
- It is approved for either horizontal or vertical installation, with the flow arrow on the body pointing in the direction of flow.
Specifications
- Type: Backflow Preventer - Ductile Iron Double Check Detector Assembly
- Size: 10"
- Connection: Flanged
- Application: Fire Protection
- Backflow Protection: Both
- MPN: 10-350DACFM
- Certifications: ASSE-1048, AWWA-C510, CSA-B64.5, UL, NSF-372
- Lead-Free: Yes
- Assembly Type: DCDA
- Hazard Protection Level: Low Health Hazard
- ASSE Standard: ASSE 1048
- USC FCCCHR Approved: No
- Fire Protection Listing: UL Classified
- Field Testable: Yes
- Shutoff Valves: NRS Gate
- Approved Orientation: Horizontal & Vertical
- Bypass Meter: CFM
Dimensions
| Size Nominal | 10" | End Connection | Flanged |
Details
| Series | 350DA | Device Type | Backflow Preventer - Ductile Iron Double Check Detector Assembly |
| Lead Free | Yes | Application | Fire Protection |
| Backflow Protection | Both | Assembly Type | DCDA |
| Hazard Rating | Low Health Hazard | ASSE Standard | ASSE 1048 |
| Fire Listing | UL Classified | Testable | Yes |
| Shutoff Valve Type | NRS Gate | Orientation | Horizontal & Vertical |
| Detector Meter | CFM | — | — |
Certifications & Standards
| ASSE-1048 | AWWA-C510 |
| CSA-B64.5 | UL |
| NSF-372 | — |
Compare with similar products
| Backflow Protection | Both
| Both
| Both
| Both
| Both
| Both
|
| Assembly Type | DCDA
| RPDA
| RPDA
| RPDA
| RPDA
| RPDA
|
| Hazard Rating | Low Health Hazard
| High Health Hazard
| High Health Hazard
| High Health Hazard
| High Health Hazard
| High Health Hazard
|
| ASSE Standard | ASSE 1048
| ASSE 1047
| ASSE 1047
| ASSE 1047
| ASSE 1047
| ASSE 1047
|
| USC Approved | — | Yes | Yes | Yes | Yes | Yes |
| Fire Listing | UL Classified
| UL Classified, C-UL Classified, FM Approved
| UL Classified, C-UL Classified, FM Approved
| UL Classified, C-UL Classified, FM Approved
| UL Classified, C-UL Classified, FM Approved
| UL Classified, C-UL Classified, FM Approved
|
| Testable | Yes | Yes | Yes | Yes | Yes | Yes |
| Shutoff Valve Type | NRS Gate
| NRS Gate
| NRS Gate
| NRS Gate
| NRS Gate
| NRS Gate
|
| Detector Meter | CFM
| GPM
| GPM
| GPM
| GPM
| GPM
|
| Series | 350DA
| 475STDA
| 475STDA
| 475STDA
| 475STDA
| 475DAV
|
| Spec Sheet | ||||||
| Install Sheet | ||||||
| Device Type | Backflow Preventer - Ductile Iron Double Check Detector Assembly
| Reduced Pressure Detector Assembly
| Reduced Pressure Detector Assembly
| Reduced Pressure Detector Assembly
| Reduced Pressure Detector Assembly
| Backflow Preventer - Z-Pattern (Vertical) Reduced Pressure Principle Detector Assembly -
|
| Size Nominal | 10"
| 8"
| 10"
| 4"
| 6"
| 4"
|
| Lead Free | Yes | Yes | Yes | Yes | Yes | Yes |
| End Connection | Flanged
| Flanged
| Flanged
| Flanged
| Flanged
| Flanged
|
| Body Material | — | Stainless
| Stainless
| Stainless
| Stainless
| Ductile Iron
|
| Application | Fire Protection
| Fire Protection
| Fire Protection
| Fire Protection
| Fire Protection
| Fire Protection
|
| Max Pressure PSI | — | 175.0 psi | 175.0 psi | 175.0 psi | 175.0 psi | 175.0 psi |
| Certifications | ASSE-1048, AWWA-C510, CSA-B64.5, UL, NSF-372
| ASSE-1047, AWWA-C550, AWWA-C606, CSA-B64.4, C-UL, UL, FM, USC, NSF-61, NSF-372
| ASSE-1047, AWWA-C550, AWWA-C606, CSA-B64.4, C-UL, UL, FM, USC, NSF-61, NSF-372
| ASSE-1047, AWWA-C550, AWWA-C606, CSA-B64.4, C-UL, UL, FM, USC, NSF-61, NSF-372
| ASSE-1047, AWWA-C550, AWWA-C606, CSA-B64.4, C-UL, UL, FM, USC, NSF-61, NSF-372
| ASSE-1047, AWWA-C550, AWWA-C606, C-UL, UL, FM, USC, NSF-61, NSF-372
|
Recommended Products
Recently Viewed
What Our Customers Say
-
Great prices and customer service!
-
Excellent service and attention, everyone was very friendly. 5 stars for Mr. Julio.
-
The best
Is ray -
No nonsense great customer service 👍
-
Got me flushing again
-
I ordered online and it arrived in excellent condition and on time.
-
Excellent service and help from the staff who work at this place
-
Great place for plumbing parts and great service
-
Professional services, excellent customer service
-
Excellent
-
These guys are pros and have everything you could need!
-
Material Always on Hand or Quick order