Zurn 1-975XLU Reduced Pressure Principle Backflow Preventer, Bronze, FNPT

SKU: 1-975XLU
Price:
Sale price$930.29 Regular price$1,108.00
Stock:

Not in regular stock. We order it, inspect it and ship it to you. Delivery times may vary.

Subtotal: $930.29

Free shipping over $200

Key Features

Assembly Type RPZ
Hazard Rating High Health Hazard
ASSE Standard ASSE 1013
Spec Sheet Download
See all product information

Similar products

Watts 3/4" Backflow Preventer LF009M3QT.34
Watts Watts 3/4" Backflow Preventer LF009M3QT.34
Sale price$738.73 Regular price$1,590.00
Watts LF007M1-QT-FZ 2
Watts LF007-QT-FZ 1/2
Compare Products

Specifications

Description

The Zurn Wilkins 1-975XLU is a 1" reduced pressure zone (RPZ) backflow preventer with FNPT connections, approved for high health hazard protection. It features a bronze body. Rated to 175 psi and up to 180°F.

The 975XLU Reduced Pressure Principle Backflow Assembly, with union ball valves, is used in high health hazard, potable water applications for protection against both backsiphonage and backpressure of contaminated water into the non-potable water supply. The wye pattern, bronze body is assembled with union ball valve shutoffs for easy body removal from the line, ideal for irrigation applications which require the removal of the valve during winter months. The 975XLU is the simplest, best, and most reliable backflow preventer in the irrigation market today.

Features

  • Union ball valves between the body and shut-off valves allow for easy removal of the body from the line
  • Ideal for high hazard, irrigation applications requiring valve removal during winter months
  • All cast bronze body and stainless steel internals provide corrosion-resistance
  • IAPMO® Listed
  • CSA® Certified
  • AWWA Compliant
  • AWWA Compliant C511

Common Questions

What hazard level is this RPZ approved for?
It is rated for high health hazard (toxic) cross-connections, so it may be used on either high or low hazard service. The assembly is listed to ASSE 1013.
Does this assembly have to be tested every year?
Yes. This is a field-testable assembly with 4 test cocks. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter. It carries USC FCCCHR approval, which many jurisdictions accept as their sole approval list.
Does the relief valve need a drain?
Yes. An RPZ relief valve is designed to discharge, and it can dump a large volume of water, so it must never be installed in a pit or below grade and the discharge must be piped to an adequate drain through an air gap. The air gap fitting is not included with this model and is ordered separately.

Specifications

  • Type: Reduced Pressure Principle Backflow Preventer
  • Size: 1"
  • Connection: FNPT
  • Body Material: Bronze
  • Max Pressure (psi): 175
  • Application: Irrigation
  • Backflow Protection: Both
  • MPN: 1-975XLU
  • Temperature: up to 180°F
  • Certifications: ASSE-1013, AWWA-C511, CSA, USC, IAPMO
  • Assembly Type: RPZ
  • Hazard Protection Level: High Health Hazard
  • ASSE Standard: ASSE 1013
  • USC FCCCHR Approved: Yes
  • Field Testable: Yes
  • Number of Test Cocks: 4

Product Information

SKUUPCSpec SheetInstall Sheet
1-975XLU 612052041384 DownloadDownload

Dimensions

Size Nominal 1" End Connection FNPT

Details

Series 975XLU Device Type Reduced Pressure Principle Backflow Preventer
Body Material Bronze Application Irrigation
Max Pressure PSI 175.0 psi Max Temp °F 180.0 °F
Backflow Protection Both Assembly Type RPZ
Hazard Rating High Health Hazard ASSE Standard ASSE 1013
USC Approved Yes Testable Yes
Test Cocks 4 ——

Certifications & Standards

ASSE-1013 AWWA-C511
CSA USC
IAPMO —

Compare with similar products

Backflow Protection
Both
Both
Both
Both
Both
Both
Assembly Type
RPZ
RPZ
RPZ
RPZ
RPZ
RPZ
Hazard Rating
High Health Hazard
High Health Hazard
High Health Hazard
High Health Hazard
High Health Hazard
High Health Hazard
ASSE Standard
ASSE 1013
ASSE 1013
ASSE 1013
ASSE 1013
ASSE 1013
ASSE 1013
USC Approved
Yes
Yes
Yes
Yes
Yes
Yes
Fire Listing
—
UL Classified, C-UL Classified
UL Classified, C-UL Classified
—
—
—
Testable
Yes
Yes
Yes
Yes
Yes
Yes
Test Cocks
4
4
4
4
4
4
Shutoff Valve Type
—
Quarter-Turn Ball
Quarter-Turn Ball
NRS Gate
NRS Gate
NRS Gate
Series
975XLU
112-975XL2
1-975XL2SAG
2-375XLFT
1-375XLFT
1-375XLFT
Spec Sheet
Install Sheet
Device Type
Reduced Pressure Principle Backflow Preventer
Backflow Preventer - Bronze Reduced Pressure Principle Assembly
Backflow Preventer - Bronze Reduced Pressure Principle Assembly
Backflow Preventer - Reduced Pressure Principle
Backflow Preventer - Reduced Pressure Principle
Backflow Preventer - Reduced Pressure Principle
Size Nominal
1"
1-1/2"
1-1/2"
2"
3/4"
1"
Lead Free
—
Yes
Yes
Yes
Yes
Yes
End Connection
FNPT
FNPT
FNPT
Flanged
Flanged
Flanged
Body Material
Bronze
Bronze
Bronze
—
—
—
Application
Irrigation
Domestic Water
Domestic Water
Domestic Water
Domestic Water
Domestic Water
Max Pressure PSI
175.0 psi
175.0 psi
175.0 psi
175.0 psi
175.0 psi
175.0 psi
Max Temp °F
180.0 °F
180.0 °F
180.0 °F
180.0 °F
180.0 °F
180.0 °F
Certifications
ASSE-1013, AWWA-C511, CSA, USC, IAPMO
ASSE-1013, AWWA-C511, CSA-B64.4, C-UL, UL, USC, NSF-61, NSF-372, IAPMO
ASSE-1013, AWWA-C511, CSA-B64.4, C-UL, UL, USC, NSF-61, NSF-372, IAPMO
ASSE-1013, AWWA-C511, CSA-B64.4, USC, NSF-61, NSF-372, IAPMO
ASSE-1013, AWWA-C511, CSA-B64.4, USC, NSF-61, NSF-372, IAPMO
ASSE-1013, AWWA-C511, CSA-B64.4, USC, NSF-61, NSF-372, IAPMO

Recommended Products

Recently Viewed

What Our Customers Say