Specifications
Description
The Zurn Wilkins 1-375ST is a 1" lead-free reduced pressure zone (RPZ) backflow preventer with Flanged connections, approved for high health hazard protection. It is rated to 175 psi and up to 180°F. This model is certified lead-free for potable-water installations.
The 375ST Reduced Pressure Principle Backflow Preventer offers high hazard protection against both backsiphonage and backpressure of contaminated water into the potable water supply. Materials include engineered plastic construction and quality 300 series stainless steel fasteners, springs, ball valves, and struts. The 375ST is utilized in systems where liquids are corrosive to copper alloys like bronze valves, including medical diagnostic equipment applications, food processing, distilleries, and breweries. It comes standard with full port QT ball valves, and features a maximum working water pressure of 175 psi, maximum working water temperature of 180°F, and hydrostatic test pressure of 350 psi.
Features
- All stainless steel and engineered plastic construction resists corrosion
- Repair Kits provide cost savings by avoiding full Backflow Preventer replacement
- Applicable for systems that are corrosive to bronze valves
- Excellent for food service use
- Low-lead law compliant
- ASSE® Listed 1013
- Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
Common Questions
- What hazard level is this RPZ approved for?
- It is rated for high health hazard (toxic) cross-connections, so it may be used on either high or low hazard service. The assembly is listed to ASSE 1013.
- Is this model legal for potable water?
- Yes. It is certified lead-free to NSF/ANSI 372, which is what state plumbing codes require for any device in a drinking-water line.
- Does this assembly have to be tested every year?
- Yes. This is a field-testable assembly with 4 test cocks. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter. It carries USC FCCCHR approval, which many jurisdictions accept as their sole approval list.
- What shutoff valves are included?
- It is supplied with non-rising stem (NRS) resilient-seated gate valves on the inlet and outlet.
- Does the relief valve need a drain?
- Yes. An RPZ relief valve is designed to discharge, and it can dump a large volume of water, so it must never be installed in a pit or below grade and the discharge must be piped to an adequate drain through an air gap. The air gap fitting is not included with this model and is ordered separately.
Specifications
- Type: Backflow Preventer - Reduced Pressure Principle, Stainless Steel
- Size: 1"
- Connection: Flanged
- Max Pressure (psi): 175
- Application: Domestic Water
- Backflow Protection: Both
- MPN: 1-375ST
- Temperature: up to 180°F
- Certifications: ASSE-1013, CSA-B64.4, USC, NSF-61, NSF-372
- Lead-Free: Yes
- Assembly Type: RPZ
- Hazard Protection Level: High Health Hazard
- ASSE Standard: ASSE 1013
- USC FCCCHR Approved: Yes
- Field Testable: Yes
- Number of Test Cocks: 4
- Shutoff Valves: NRS Gate
Dimensions
| Size Nominal | 1" | End Connection | Flanged |
Details
| Series | 375ST | Device Type | Backflow Preventer - Reduced Pressure Principle, Stainless Steel |
| Lead Free | Yes | Application | Domestic Water |
| Max Pressure PSI | 175.0 psi | Max Temp °F | 180.0 °F |
| Backflow Protection | Both | Assembly Type | RPZ |
| Hazard Rating | High Health Hazard | ASSE Standard | ASSE 1013 |
| USC Approved | Yes | Testable | Yes |
| Test Cocks | 4 | Shutoff Valve Type | NRS Gate |
Certifications & Standards
| ASSE-1013 | CSA-B64.4 |
| USC | NSF-61 |
| NSF-372 | — |
Compare with similar products
| Backflow Protection | Both
| Both
|
| Assembly Type | RPZ
| RPZ
|
| Hazard Rating | High Health Hazard
| High Health Hazard
|
| ASSE Standard | ASSE 1013
| ASSE 1013
|
| USC Approved | Yes | Yes |
| Testable | Yes | Yes |
| Test Cocks | 4
| 4
|
| Shutoff Valve Type | NRS Gate
| Quarter-Turn Ball
|
| Series | 375ST
| 112-975XL2
|
| Spec Sheet | ||
| Install Sheet | ||
| Device Type | Backflow Preventer - Reduced Pressure Principle, Stainless Steel
| Backflow Preventer - Bronze Reduced Pressure Principle Assembly
|
| Size Nominal | 1"
| 1-1/2"
|
| Lead Free | Yes | Yes |
| End Connection | Flanged
| FNPT
|
| Application | Domestic Water
| Domestic Water
|
| Max Pressure PSI | 175.0 psi | 175.0 psi |
| Max Temp °F | 180.0 °F | 180.0 °F |
| Certifications | ASSE-1013, CSA-B64.4, USC, NSF-61, NSF-372
| ASSE-1013, AWWA-C511, CSA-B64.4, C-UL, UL, USC, NSF-61, NSF-372, IAPMO
|
Recommended Products
Recently Viewed
What Our Customers Say
-
absolutely the most helpful gracious and polite people I have dealt with in a very long time. thank you so much!!
-
Professional services, excellent customer service
-
Great prices and customer service!
-
Ray Rhodes thanks for your help. 5 star service at City Supply.
-
Material Always on Hand or Quick order
-
No nonsense great customer service 👍
-
They had what I needed to replace the stem on my 60 year old bathroom showers. Great service.
-
Excellent service
-
Excellent service and help from the staff who work at this place
-
Great customer service part was already waiting for me at the counter!!!! it don’t get no better than that!!
-
I recommend them to everyone, they have EVERYTHING, great customer service and always come through for our day to day needs.
-
Excellent