Watts LF009-NRS-FS 2 1/2 Lead-Free RPZ Backflow Preventer, Cast Iron

SKU: F122612
Price:
Sale price$7,290.06 Regular price$10,471.00
Stock:

Not in regular stock. We order it, inspect it and ship it to you. Delivery times may vary.

Subtotal: $7,290.06

Free shipping over $200

Key Features

Assembly Type RPZ
Hazard Rating High Health Hazard
ASSE Standard ASSE 1013
Spec Sheet Download
See all product information

Similar products

Watts 3/4" Backflow Preventer LF009M3QT.34
Watts Watts 3/4" Backflow Preventer LF009M3QT.34
Sale price$738.73 Regular price$1,590.00
Watts LF007M1-QT-FZ 2
Watts LF007-QT-FZ 1/2
Compare Products

Specifications

Description

The Watts LF009-NRS-FS 2 1/2 is a 2-1/2" lead-free reduced pressure zone (RPZ) backflow preventer, approved for high health hazard protection. It features a cast iron body and a silicone seat. Rated to 175 psi. This model is certified lead-free for potable-water installations.

This 2 1/2 inch lead free reduced pressure zone backflow preventer assembly is designed to prevent the flow of polluted water from entering into the potable water supply due to backsiphonage and or backpressure. Ideal for protection in continuous pressure piping applications and at cross-connections identified as health hazards and for contaminants at the service line entrance. This assembly consists of a cast iron body, non-rising stem resilient seated gate valves, top mounted test cocks, two in-line independent check valves, captured springs and replaceable check seats with an internal relief valve for reduced space requirements. The coating on this backflow assembly uses ArmorTek®, a patented 3-part advanced epoxy coating system designed to limit both microbial induced (MIC) and exposed metal substrate corrosion. This backflow assembly includes flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. When paired with an add on connection kit, the sensor is activated to relay alerts for potential flooding events. Connection kit options include BMS, cellular communication, and the Sensor Control Monitor which enables integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.

Features

  • Features a flood sensor with SentryPlus Alert technology to detect continuous discharge from the relief valve
  • Add-on sensor connection kit to extend flood monitoring on compatible assemblies
  • Integrates with the Sensor Control Monitor to deliver maintenance alerts to BAS via RS-485 Modbus or the Nexa platform by Wi-Fi connectivity
  • Utilizes advanced ArmorTek coating technology to resist corrosion of internals
  • Cast iron body construction with patented 3-part advanced epoxy coating system designed to limit both microbial induced (MIC) and exposed metal substrate corrosion
  • Non-rising stem resilient seated gate valves
  • Compact, space saving design
  • Includes: Test Cocks
  • Includes: Flood Sensor

Common Questions

What hazard level is this RPZ approved for?
It is rated for high health hazard (toxic) cross-connections, so it may be used on either high or low hazard service. The assembly is listed to ASSE 1013.
Is this model legal for potable water?
Yes. It is certified lead-free to NSF/ANSI 372, which is what state plumbing codes require for any device in a drinking-water line.
Does this assembly have to be tested every year?
Yes. This is a field-testable assembly with 4 test cocks. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter. It carries USC FCCCHR approval, which many jurisdictions accept as their sole approval list.
What shutoff valves are included?
It is supplied with non-rising stem (NRS) resilient-seated gate valves on the inlet and outlet.
Is this listed for fire protection service?
Yes — it is UL Classified and FM Approved, the listings normally required for a backflow device on a fire sprinkler supply.
Does the relief valve need a drain?
Yes. An RPZ relief valve is designed to discharge, and it can dump a large volume of water, so it must never be installed in a pit or below grade and the discharge must be piped to an adequate drain through an air gap. The air gap fitting is not included with this model and is ordered separately. This model includes the SentryPlus Alert flood sensor, which signals a relief-valve discharge before it becomes a flood.

Specifications

  • Type: RPZ
  • Size: 2-1/2"
  • Inlet Size: 2-1/2"
  • Outlet Size: 2-1/2"
  • Body Material: Cast Iron
  • Seat / Seal Material: Silicone
  • Max Pressure (psi): 175
  • Application: Domestic Water
  • Backflow Protection: Both
  • Operation: Continuous
  • Country of Origin: United States
  • Warranty: 1 Year Limited
  • MPN: LF009-NRS-FS 2 1/2
  • Certifications: ASSE-1013, CSA-B64, UL, FM, USC, IAPMO
  • Lead-Free: Yes
  • Assembly Type: RPZ
  • Hazard Protection Level: High Health Hazard
  • ASSE Standard: ASSE 1013
  • USC FCCCHR Approved: Yes
  • Fire Protection Listing: UL Classified;FM Approved
  • Field Testable: Yes
  • Number of Test Cocks: 4
  • Shutoff Valves: NRS Gate
  • Flood Sensor (SentryPlus Alert): Yes
  • Strainer Included: No
  • Air Gap Fitting Included: No

Product Information

SKUUPCCountry of OriginWarrantySpec SheetInstall Sheet
F122612 098268520033 United States 1 Year Limited DownloadDownload

Dimensions

Size Nominal 2-1/2" Inlet Size 2-1/2"
Outlet Size 2-1/2" ——

Details

Series LF009 Device Type RPZ
Lead Free Yes Body Material Cast Iron
Seat Material Silicone Application Domestic Water
Operation Continuous Max Pressure PSI 175.0 psi
Backflow Protection Both Options Test Cocks, Flood Sensor
Min Temp °F 33.0 °F Assembly Type RPZ
Hazard Rating High Health Hazard ASSE Standard ASSE 1013
USC Approved Yes Fire Listing UL Classified, FM Approved
Testable Yes Test Cocks 4
Shutoff Valve Type NRS Gate Flood Sensor Yes

Certifications & Standards

ASSE-1013 CSA-B64
UL FM
USC IAPMO

Compare with similar products

Backflow Protection
Both
Both
Both
Both
Both
Both
Assembly Type
RPZ
RPZ
RPZ
RPZ
RPZ
RPZ
Hazard Rating
High Health Hazard
High Health Hazard
High Health Hazard
High Health Hazard
High Health Hazard
High Health Hazard
ASSE Standard
ASSE 1013
ASSE 909, ASSE 1013
ASSE 909, ASSE 1013
ASSE 1013
ASSE 909, ASSE 1013
ASSE 909, ASSE 1013
USC Approved
Yes
Yes
Yes
Yes
Yes
Yes
Fire Listing
UL Classified, FM Approved
—
—
UL Classified, FM Approved
—
—
Testable
Yes
Yes
Yes
Yes
Yes
Yes
Test Cocks
4
4
4
4
4
4
Shutoff Valve Type
NRS Gate
Quarter-Turn Ball
Quarter-Turn Ball
Quarter-Turn Ball
Quarter-Turn Ball
Quarter-Turn Ball
Orientation
—
Horizontal & Vertical
Horizontal & Vertical
—
Horizontal & Vertical
Horizontal & Vertical
Flood Sensor
Yes
Yes
Yes
—
—
—
Series
LF009
LF909 Small
LF909 Small
LF009
LF909 Small
LF909 Small
Country Of Origin
United States
United States
United States
United States
United States
United States
Warranty
1 Year Limited
1 Year Limited
1 Year Limited
1 Year Limited
1 Year Limited
1 Year Limited
Spec Sheet
Install Sheet
Device Type
RPZ
RPZ
RPZ
RPZ
RPZ
RPZ
Size Nominal
2-1/2"
1-1/4"
1"
3/4"
1-1/4"
1"
Inlet Size
2-1/2"
1-1/4"
1"
3/4"
1-1/4"
1"
Outlet Size
2-1/2"
1-1/4"
1"
3/4"
1-1/4"
1"
Lead Free
Yes
Yes
Yes
Yes
Yes
Yes
Body Material
Cast Iron
Copper
Copper
Bronze
Copper
Copper
Seat Material
Silicone
—
—
Silicone
—
—
Application
Domestic Water
Domestic Water
Domestic Water
Domestic Water
Domestic Water
Domestic Water
Operation
Continuous
Continuous
Continuous
Continuous
Continuous
Continuous
Max Pressure PSI
175.0 psi
175.0 psi
175.0 psi
175.0 psi
175.0 psi
175.0 psi
Max Temp °F
—
140.0 °F
140.0 °F
—
140.0 °F
140.0 °F
Certifications
ASSE-1013, CSA-B64, UL, FM, USC, IAPMO
ASSE-909, ASSE-1013, CSA-B64, USC, IAPMO
ASSE-909, ASSE-1013, CSA-B64, USC, IAPMO
ASSE-1013, CSA-B64, UL, FM, USC, IAPMO
ASSE-909, ASSE-1013, CSA-B64, USC, IAPMO
ASSE-909, ASSE-1013, CSA-B64, USC, IAPMO
Options
Test Cocks, Flood Sensor
Test Cocks, Flood Sensor
Test Cocks, Flood Sensor
Test Cocks
Test Cocks
Test Cocks
Min Temp °F
33.0 °F
33.0 °F
33.0 °F
33.0 °F
33.0 °F
33.0 °F

Recommended Products

Recently Viewed

What Our Customers Say