Specifications
Description
The Sloan MCR-4011-AL-004 is a controller, a Sloan Valve genuine replacement part.
The Sloan MCR-4011-A (formerly MCR-4001) is a four input/output (4 I/O) communicating controller that is used with Sloan PWT push buttons and solenoids to control water closets, lavatories, and shower systems. The MCR-4011-A communicating controller can be pre-programmed for specific activations and run-times along with lockouts for a predetermined length of time for improper usage as well as for water conservation purposes. Sloan PWT communicating controllers can be connected to PWT Management Consoles utilizing a FT-10 (twisted pair) network so that the entire network of connected controllers and fixtures can be monitored and programs or settings can be changed. The MCR-4011-A controller has a hinged door and enclosure that is IP-53 rated, the four input/output ports are 4-pin RJ-11 connections. The Sloan PWT Systems allow a facility to take control of their plumbing systems to minimize mis-use as well as manage water usage. Pre-programed for water closet, lavatory and shower combination set-up. Program set for 20 seonds of lavatory hot water run time, 10 seconds of lavatory cold water run time, 1 hour water closet lockout, and 1 & 2 minute shower cycle.
Features
- PWT System 4-I/O Twisted Pair Communicating Controller, PWT MCR-4011AL-004 Program All
- IP-53 rated enclosure w/ hinged door
- Four input/output controller used with PWT push buttons, electronic flushometers and solenoids to control water closets, lavatories and showers
- Can connect to a computer managed, FT-10 (twisted pair) network.
- Four Input/Output twisted pair communicating control
- Fixture usage can be pre-programmed for delays, scheduled runtimes or complete lockouts to prohibit improper usage of water closets, lavatories and showers
- May be connected to PWT management console for communicating solution
- Input and output diagnostic LEDs give immediate information about service issues
- Easy access reset button
- Different controllers offer oversight of various combinations of fixtures
Common Questions
- What flush valves does this part fit?
- Sloan's own parts data does not name a specific series for this exact code. Confirm fit against your flushometer's model number before ordering, or contact CSG to verify.
- Is this a genuine Sloan part?
- Yes. The MCR-4011-AL-004 is a factory-original Sloan Valve Company replacement part, not an aftermarket equivalent.
Specifications
- MPN: MCR-4011-AL-004
- Certifications: Buy American Act
- Product Role: Controller
- Accessory Type: Controller
Details
| Series | MCR-4011-A | Product Role | Controller |
| Accessory Type | Controller | — | — |
Certifications & Standards
| Buy American Act | — |
Recommended Products
Recently Viewed
What Our Customers Say
-
Excellent service
-
Great prices and customer service!
-
Good service
-
Needed a faucet quick. They had what we needed within 5 minutes and were all so nice
-
Great customer services
-
Great customer service part was already waiting for me at the counter!!!! it don’t get no better than that!!
-
Material Always on Hand or Quick order
-
A beautiful and smart woman with a helpful heart that is a surprise to find in a plumbing supply co., Nekell.
-
These guys are pros and have everything you could need!
-
Excellent service at the counter. Manuel and Ray are super knowledgeable and helpful. Thank you!
-
Excellent
-
They had what I needed to replace the stem on my 60 year old bathroom showers. Great service.