{"product_id":"zurn-34-975xl3seu","title":"Zurn 34-975XL3SEU 3\/4\" Lead-Free Backflow Preventer - Bronze Reduced Pressure Principle Assembly with EZ Swap Modular Check Valves","description":"\u003cp\u003eThe Zurn Wilkins 34-975XL3SEU is a 3\/4\" lead-free reduced pressure zone (RPZ) backflow preventer with FNPT connections, approved for high health hazard protection. It features a bronze body. This model is certified lead-free for potable-water installations.\u003c\/p\u003e\u003cp\u003eThe Wilkins 975XL3 Reduced Pressure Principle Backflow Assembly provides high hazard protection against backsiphonage and backpressure in potable water applications. The 975XL3 series offers the most compact and lightest bronze small backflow available on the market today. The design combines the robust time-tested construction of our 975XL\/XL2 series with the innovative modular check EZSwap® design of our 375 series allowing for ease of repair and greater labor savings compared to all other brands.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCompact and shortest bronze small backflow valve on the market allowing for installation versatility\u003c\/li\u003e\n\u003cli\u003eAll-bronze body ensures durability against the elements, with a Noryl®* check body and stainless-steel fasteners to resist corrosion over time.\u003c\/li\u003e\n\u003cli\u003eEZSWAP® modular check with top access speeds up repairs and replacements\u003c\/li\u003e\n\u003cli\u003eTest ports located on valve’s centerline make install and testing easy\u003c\/li\u003e\n\u003cli\u003eInterlocking connected checks provide ¼ turn to access and disassemble.\u003c\/li\u003e\n\u003cli\u003eLow-cost repair kits extend the lifespan at a significantly lower cost\u003c\/li\u003e\n\u003cli\u003eLead Free* (0.25% max. weighted average lead content)\u003c\/li\u003e\n\u003cli\u003eASSE Listed, UPC® Listed, Meets NSF\/ANSI\/CAN 61 \u0026amp; 372 requirements; Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California; Safe Drinking Water Act Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat hazard level is this RPZ approved for?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eIt is rated for high health hazard (toxic) cross-connections, so it may be used on either high or low hazard service.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eIs this model legal for potable water?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. It is certified lead-free to NSF\/ANSI 372, which is what state plumbing codes require for any device in a drinking-water line.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eDoes this assembly have to be tested every year?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. This is a field-testable assembly with 4 test cocks. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter. It carries USC FCCCHR approval, which many jurisdictions accept as their sole approval list.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat shutoff valves are included?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eIt is supplied with quarter-turn ball valves on the inlet and outlet.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eDoes the relief valve need a drain?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. An RPZ relief valve is designed to discharge, and it can dump a large volume of water, so it must never be installed in a pit or below grade and the discharge must be piped to an adequate drain through an air gap. The air gap fitting is not included with this model and is ordered separately.\u003c\/dd\u003e\n\u003c\/dl\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Backflow Preventer - Bronze Reduced Pressure Principle Assembly with EZ Swap Modular Check Valves\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 3\/4\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e FNPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody Material:\u003c\/strong\u003e Bronze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Domestic Water\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow Protection:\u003c\/strong\u003e Both\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e 34-975XL3SEU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e USC, NSF-61, NSF-372, IAPMO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly Type:\u003c\/strong\u003e RPZ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazard Protection Level:\u003c\/strong\u003e High Health Hazard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSC FCCCHR Approved:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Testable:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Test Cocks:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShutoff Valves:\u003c\/strong\u003e Quarter-Turn Ball\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Zurn","offers":[{"title":"Default Title","offer_id":55656211251499,"sku":"34-975XL3SEU","price":1186.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0277\/3168\/9577\/files\/1-975XL3_AL_1e957349-68e8-4cf0-848f-512e74994295.jpg?v=1790042362","url":"https:\/\/citysupplygroup.com\/products\/zurn-34-975xl3seu","provider":"City Supply","version":"1.0","type":"link"}