{"product_id":"zurn-14-35xlvch","title":"Zurn 14-35XLVCH 1\/4\" Lead-Free Atmospheric Vacuum Breaker, Brass, FNPT","description":"\u003cp\u003eThe Zurn Wilkins 14-35XLVCH is a 1\/4\" lead-free anti-siphon (atmospheric) vacuum breaker with FNPT connections, approved for high health hazard protection. It features a brass body. Rated to 125 psi and up to 180°F. This model is certified lead-free for potable-water installations.\u003c\/p\u003e\u003cp\u003eThe Wilkins 35XLVCH Atmospheric Vacuum Breaker with chrome plated finish for high hazard protection in non-continuous pressure applications subject to backsiphonage conditions\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProvided with vertical inlet and outlet connections\u003c\/li\u003e\n\u003cli\u003ePolished chrome finish\u003c\/li\u003e\n\u003cli\u003eSuitable for salon basins and sinks\u003c\/li\u003e\n\u003cli\u003eLow-lead law compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat hazard level is this AVB approved for?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eIt is rated for high health hazard (toxic) cross-connections, but only against backsiphonage. The assembly is listed to ASSE 1001.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eIs this model legal for potable water?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. It is certified lead-free to NSF\/ANSI 372, which is what state plumbing codes require for any device in a drinking-water line.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eCan this device be field tested?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eNo. It is not a testable assembly, so it cannot be certified by a backflow tester. Where a jurisdiction requires an annually tested device, specify a testable assembly (double check, RPZ, or PVB) instead.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWill this protect against backpressure?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eNo. An anti-siphon (atmospheric) vacuum breaker protects against backsiphonage only. It will not stop backflow caused by backpressure -- a downstream pump, elevated piping or a boiler -- which requires a double check or RPZ assembly instead.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eHow does this have to be installed?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eIt must be installed vertically (upright), above the highest downstream outlet, per its installation instructions and ASSE listing.\u003c\/dd\u003e\n\u003c\/dl\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Atmospheric Vacuum Breaker\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1\/4\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e FNPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody Material:\u003c\/strong\u003e Brass\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Pressure (psi):\u003c\/strong\u003e 125\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Domestic Water\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow Protection:\u003c\/strong\u003e Backsiphonage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e 14-35XLVCH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e up to 180°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e ASSE-1001, CSA, NSF-372, IAPMO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly Type:\u003c\/strong\u003e AVB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazard Protection Level:\u003c\/strong\u003e High Health Hazard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eASSE Standard:\u003c\/strong\u003e ASSE 1001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSC FCCCHR Approved:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Testable:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Test Cocks:\u003c\/strong\u003e 0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproved Orientation:\u003c\/strong\u003e Vertical\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Zurn","offers":[{"title":"Default Title","offer_id":55656212332843,"sku":"14-35XLVCH","price":106.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0277\/3168\/9577\/files\/14-35XLVCH_AF.jpg?v=1790042388","url":"https:\/\/citysupplygroup.com\/products\/zurn-14-35xlvch","provider":"City Supply","version":"1.0","type":"link"}