{"product_id":"zurn-12-zw1070xl","title":"Zurn 12-ZW1070XL 1\/2\" Lead-Free Aqua-Gard® Thermostatic Mixing Valve - Point of Use (ASSE 1070)","description":"\u003cp\u003eThe Zurn Wilkins 12-ZW1070XL is a 1\/2\" lead-free point-of-use thermostatic mixing valve with FNPT connections. It blends hot and cold water to a field-set outlet temperature of 95°F to 115°F. It is listed to ASSE-1070. It features a lead-free bronze body. Rated to 125 psi. This model is certified lead-free for potable-water installations.\u003c\/p\u003e\u003cp\u003eThe Aqua-Gard® ZW1070XL Thermostatic Mixing Valve is designed to be installed at the point of use (residential and most light commercial installations) to mix hot and cold water from the distribution system to a final safer temperature.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDesigned for installation at the point of use\u003c\/li\u003e\n\u003cli\u003eSuitable for multiple fixtures\u003c\/li\u003e\n\u003cli\u003eLow-lead law compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eCan I install this at a lavatory or sink - is it ASSE 1070 listed?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. It is listed to ASSE 1070, the point-of-use scald-protection standard, so it is legal to install serving a lavatory, sink or similar fixture. Its outlet adjusts from 95°F to 115°F.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eDoes the hot and cold supply pressure matter?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes - the maximum allowed pressure differential between the hot and cold inlets is 15 psi. A bigger imbalance than that is a real install-failure mode: the valve cannot hold its set temperature if one side is starved relative to the other.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eDoes it have integral checks?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. Check valves and strainer screens are built into the hot and cold inlets to stop cross-flow between the supplies and keep debris off the thermostat.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat is the hottest water this can accept on the hot side?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eUp to 195°F. The valve blends it down to the safe outlet range regardless of how hot the supply runs, within its rated pressure and flow.\u003c\/dd\u003e\n\u003c\/dl\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Aqua-Gard® Thermostatic Mixing Valve - Point of Use (ASSE 1070)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 1\/2\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInlet Size:\u003c\/strong\u003e 1\/2\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet Size:\u003c\/strong\u003e 1\/2\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e FNPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody Material:\u003c\/strong\u003e Lead-Free Bronze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Pressure (psi):\u003c\/strong\u003e 125\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Domestic Water\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e 12-ZW1070XL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e ASSE-1070, IAPMO, CSA-B125.70, NSF\/ANSI\/CAN 61-9 Q≤1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eASSE Listing:\u003c\/strong\u003e ASSE-1070\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Point:\u003c\/strong\u003e Point of Use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet Temp — Min (°F):\u003c\/strong\u003e 95\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet Temp — Max (°F):\u003c\/strong\u003e 115\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Hot Inlet Temp (°F):\u003c\/strong\u003e 195\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Controllable Flow (gpm):\u003c\/strong\u003e 0.25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Flow (gpm):\u003c\/strong\u003e 10.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral Checks \u0026amp; Filter Screens:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Hot\/Cold Pressure Differential (psi):\u003c\/strong\u003e 15\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Zurn","offers":[{"title":"Default Title","offer_id":55656988836139,"sku":"12-ZW1070XL","price":286.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0277\/3168\/9577\/files\/12-zw1070xlpf_AF_3071d929-3bba-4306-b097-509fcc871308.jpg?v=1790047821","url":"https:\/\/citysupplygroup.com\/products\/zurn-12-zw1070xl","provider":"City Supply","version":"1.0","type":"link"}