{"product_id":"watts-t062725","title":"Watts 007M1DCDA-OSY-CFM-FZ 2 Double Check Backflow Preventer, Bronze","description":"\u003cp\u003eThe Watts 007M1DCDA-OSY-CFM-FZ 2 is a 2\" double check detector assembly (DCDA), approved for low health hazard protection. It features a bronze body and a silicone seat. Rated to 700 psi.\u003c\/p\u003e\u003cp\u003eThis 2 inch double check detector backflow preventer assembly is designed to prevent the reverse flow of fire protection substances and water of non-potable quality from being pumped or siphoned into the potable water supply due to backsiphonage and or backpressure in accordance with national plumbing codes and water authority requirements. It is ideal for protection at cross-connections identified as non-health hazards such as on fire protection systems and from other contaminants found at the service line entrance. This compact modular design with a single access cover for easy maintenance is approved for horizontal and vertical flow up installation. It consists of a cast bronze body, outside stem and yoke resilient seated gate valves, captured spring check valves, and four test cocks. It comes with a cubic feet per minute meter to detect underground leaks and unauthorized water use. The double check valve includes a freeze sensor for use with SentryPlus Alert® technology to signal facility personnel when temperature nears and reaches the freezing point. Freeze alerts feature available with add-on connection kit for Wi-Fi networks, building management systems (BMS), irrigation management systems (IMS).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIncludes a freeze sensor for use with SentryPlus Alert technology to signal facility personnel when temperature nears and reaches the freezing point\u003c\/li\u003e\n\u003cli\u003eAvailable freeze sensor connection kit to activate a monitoring system that trigger alerts for low and freezing temperatures\u003c\/li\u003e\n\u003cli\u003eCast bronze body construction\u003c\/li\u003e\n\u003cli\u003eFurnished with a cubic feet per minute meter\u003c\/li\u003e\n\u003cli\u003eFreeze alerts feature available with add-on connection kit for Wi-Fi networks, building management systems (BMS), and irrigation management systems (IMS)\u003c\/li\u003e\n\u003cli\u003eReplaceable seats and discs\u003c\/li\u003e\n\u003cli\u003eNo special tools are required for servicing\u003c\/li\u003e\n\u003cli\u003eIncludes: Test Cocks\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat hazard level is this DCDA approved for?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eIt is rated for low health hazard (non-toxic, \"pollutant\") cross-connections only. Where the substance downstream could be a health hazard, codes require a reduced pressure zone (RPZ) assembly instead. The assembly is listed to ASSE 1048.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eCan this be installed on potable water?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eNo. This model is not certified lead-free, so it may not be installed in potable water systems in states enforcing the NSF\/ANSI 372 weighted-average lead rule. Use it on non-potable service — fire lines, irrigation or industrial water — or order the LF (lead-free) version of this model for drinking-water use.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eDoes this assembly have to be tested every year?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. This is a field-testable assembly. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter. It carries USC FCCCHR approval, which many jurisdictions accept as their sole approval list.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat shutoff valves are included?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eIt is supplied with outside screw and yoke (OS\u0026amp;Y) gate valves on the inlet and outlet. OS\u0026amp;Y gates give the visible open\/shut indication that fire-line and many water-authority specs require.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eIs this suitable for a fire sprinkler line?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. Detector assemblies are built for fire sprinkler service: the metered bypass registers the low flows that reveal a leak or an unauthorized tap on the fire line. This model is UL Classified. The bypass meter reads in CFM.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eHow does this have to be installed?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eIt is approved for either horizontal or vertical installation, with the flow arrow on the body pointing in the direction of flow.\u003c\/dd\u003e\n\u003c\/dl\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Double Check\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 2\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInlet Size:\u003c\/strong\u003e 2\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet Size:\u003c\/strong\u003e 2\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody Material:\u003c\/strong\u003e Bronze\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeat \/ Seal Material:\u003c\/strong\u003e Silicone\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Pressure (psi):\u003c\/strong\u003e 700\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Fire Protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow Protection:\u003c\/strong\u003e Both\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e United States\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1 Year Limited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e 007M1DCDA-OSY-CFM-FZ 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e ASSE-1048, UL, USC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly Type:\u003c\/strong\u003e DCDA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazard Protection Level:\u003c\/strong\u003e Low Health Hazard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eASSE Standard:\u003c\/strong\u003e ASSE 1048\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSC FCCCHR Approved:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire Protection Listing:\u003c\/strong\u003e UL Classified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Testable:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShutoff Valves:\u003c\/strong\u003e OSY Gate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproved Orientation:\u003c\/strong\u003e Horizontal \u0026amp; Vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlood Sensor (SentryPlus Alert):\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrainer Included:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Gap Fitting Included:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBypass Meter:\u003c\/strong\u003e CFM\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Watts","offers":[{"title":"Default Title","offer_id":54935386849579,"sku":"T062725","price":9125.29,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0277\/3168\/9577\/files\/56ff0ce9e795295da6f7d1c65ebdbf20b8b92f48_f3556de3-ddb2-42c6-9c1f-9d3c67120835.jpg?v=1785983746","url":"https:\/\/citysupplygroup.com\/products\/watts-t062725","provider":"City Supply","version":"1.0","type":"link"}