{"product_id":"watts-f124736","title":"Watts LF957RPDA-OSY-CFM-FS 10 Lead-Free RPZ Backflow Preventer, Stainless, Flanged","description":"\u003cp\u003eThe Watts LF957RPDA-OSY-CFM-FS 10 is a 10\" lead-free reduced pressure detector assembly (RPDA) with Flanged connections, approved for high health hazard protection. It features a stainless body and a silicone seat. Rated to 175 psi and 33°F to 110°F. This model is certified lead-free for potable-water installations.\u003c\/p\u003e\u003cp\u003eThis 10 inch lead free reduced pressure detector backflow preventer assembly help stop the reverse flow of liquids due to backpressure or backsiphonage, where potential health hazard exists. Extremely compact and lighter than traditional designs it is approved for horizontal pattern installation. This assembly consists of a stainless steel body with a quick access sleeve, torsion spring check valves, outside stem and yoke resilient seated gate valves, test cocks, corrosive resistant bottom mounted pressure relief valve, and comes furnished with a cubic per minute meter to detect underground leaks and unauthorized water use. This backflow assembly contains a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. When paired with an add on connection kit, the sensor is activated to relay alerts for potential flooding events. Connection kit options include BMS, cellular communication, and the Sensor Control Monitor which enables integration with BAS via RS-485 Modbus or the Nexa® platform through Wi-Fi.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFeatures a flood sensor with SentryPlus Alert technology to detect continuous discharge from the relief valve\u003c\/li\u003e\n\u003cli\u003eAdd-on sensor connection kit to extend flood monitoring on compatible assemblies\u003c\/li\u003e\n\u003cli\u003eIntegrates with the Sensor Control Monitor to deliver maintenance alerts to BAS via RS-485 Modbus or the Nexa platform by Wi-Fi connectivity\u003c\/li\u003e\n\u003cli\u003eStainless steel for corrosion resistance\u003c\/li\u003e\n\u003cli\u003eUL and FM outside stem and yoke resilient seated gate valves\u003c\/li\u003e\n\u003cli\u003e150 pound ANSI\/AWWA CL D flanged\u003c\/li\u003e\n\u003cli\u003eFurnished with a cubic foot per minute meter\u003c\/li\u003e\n\u003cli\u003eCompact construction for smaller enclosures\u003c\/li\u003e\n\u003cli\u003eBottom mounted relief valve reduces clearance requirements when installed against an outside wall\u003c\/li\u003e\n\u003cli\u003eIncludes: Test Cocks\u003c\/li\u003e\n\u003cli\u003eIncludes: Flood Sensor\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat hazard level is this RPDA approved for?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eIt is rated for high health hazard (toxic) cross-connections, so it may be used on either high or low hazard service. The assembly is listed to ASSE 1047.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eIs this model legal for potable water?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. It is certified lead-free to NSF\/ANSI 372, which is what state plumbing codes require for any device in a drinking-water line.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eDoes this assembly have to be tested every year?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. This is a field-testable assembly. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter. It carries USC FCCCHR approval, which many jurisdictions accept as their sole approval list.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat shutoff valves are included?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eIt is supplied with outside screw and yoke (OS\u0026amp;Y) gate valves on the inlet and outlet. OS\u0026amp;Y gates give the visible open\/shut indication that fire-line and many water-authority specs require.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eIs this suitable for a fire sprinkler line?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. Detector assemblies are built for fire sprinkler service: the metered bypass registers the low flows that reveal a leak or an unauthorized tap on the fire line. This model is UL Classified and FM Approved. The bypass meter reads in CFM.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eHow does this have to be installed?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eIt is approved for horizontal installation only, with the flow arrow on the body pointing in the direction of flow.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eDoes the relief valve need a drain?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. An RPZ relief valve is designed to discharge, and it can dump a large volume of water, so it must never be installed in a pit or below grade and the discharge must be piped to an adequate drain through an air gap. The air gap fitting is not included with this model and is ordered separately. This model includes the SentryPlus Alert flood sensor, which signals a relief-valve discharge before it becomes a flood.\u003c\/dd\u003e\n\u003c\/dl\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e RPZ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 10\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInlet Size:\u003c\/strong\u003e 10\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet Size:\u003c\/strong\u003e 10\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Flanged\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody Material:\u003c\/strong\u003e Stainless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeat \/ Seal Material:\u003c\/strong\u003e Silicone\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Pressure (psi):\u003c\/strong\u003e 175\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Fire Protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow Protection:\u003c\/strong\u003e Both\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e United States\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1 Year Limited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e LF957RPDA-OSY-CFM-FS 10\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e 33°F to 110°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e UL, FM, USC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly Type:\u003c\/strong\u003e RPDA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazard Protection Level:\u003c\/strong\u003e High Health Hazard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eASSE Standard:\u003c\/strong\u003e ASSE 1047\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSC FCCCHR Approved:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire Protection Listing:\u003c\/strong\u003e UL Classified;FM Approved\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Testable:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShutoff Valves:\u003c\/strong\u003e OSY Gate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproved Orientation:\u003c\/strong\u003e Horizontal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlood Sensor (SentryPlus Alert):\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrainer Included:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Gap Fitting Included:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBypass Meter:\u003c\/strong\u003e CFM\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Watts","offers":[{"title":"Default Title","offer_id":54935492067627,"sku":"F124736","price":26148.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0277\/3168\/9577\/files\/a3cbebf04bdd0b1a025e5e5f8abfeaa2846a1826_2d1c711b-47fd-484f-bfe9-489cfb1f6aac.jpg?v=1785984150","url":"https:\/\/citysupplygroup.com\/products\/watts-f124736","provider":"City Supply","version":"1.0","type":"link"}