{"product_id":"watts-88007506","title":"Watts LF709-OSY NYC 4 Lead-Free Double Check Backflow Preventer, Cast Iron, Flanged","description":"\u003cp\u003eThe Watts LF709-OSY NYC 4 is a 4\" lead-free double check valve assembly with Flanged connections, approved for low health hazard protection. It features a cast iron body. Rated to 175 psi. This model is certified lead-free for potable-water installations.\u003c\/p\u003e\u003cp\u003eThis 4 inch lead free double check valve backflow preventer assembly is designed to prevent the reverse flow of contaminated water of non-potable quality from being pumped or siphoned into the potable water supply due to backsiphonage and or backpressure. Ideal for protection at cross-connections identified as non-health hazard applications and contaminants found at the service line. This assembly consists of an fused epoxy coated cast iron body, OSY resilient seated gate valves, test cocks, and a modular check design with center stem guide. The captured spring is accessible through a bolted cover plate. The coating on this backflow assembly uses ArmorTek®, a patented 3-part advanced epoxy coating system designed to limit both microbial induced (MIC) and exposed metal substrate corrosion. This NYC version comes with four sets of 304SS bolts\/nuts with a 1\/4 inch hole drilled axially through the bolt to properly tag backflow preventers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUtilizes advanced ArmorTek coating technology to resist corrosion of internals\u003c\/li\u003e\n\u003cli\u003eCast iron body construction with patented 3-part advanced epoxy coating system designed to limit both microbial induced (MIC) and exposed metal substrate corrosion\u003c\/li\u003e\n\u003cli\u003eOutside stem and yoke gate valves\u003c\/li\u003e\n\u003cli\u003eMaximum flow at low pressure drop\u003c\/li\u003e\n\u003cli\u003eDrilled bolts to eliminate flange drilling\u003c\/li\u003e\n\u003cli\u003eIncludes: Test Cocks\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Questions\u003c\/strong\u003e\u003c\/p\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat hazard level is this Double Check approved for?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eIt is rated for low health hazard (non-toxic, \"pollutant\") cross-connections only. Where the substance downstream could be a health hazard, codes require a reduced pressure zone (RPZ) assembly instead. The assembly is listed to ASSE 1015.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eIs this model legal for potable water?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. It is certified lead-free to NSF\/ANSI 372, which is what state plumbing codes require for any device in a drinking-water line.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eDoes this assembly have to be tested every year?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes. This is a field-testable assembly with 4 test cocks. Most water authorities require it to be tested and certified by a licensed backflow tester at installation and annually thereafter. It carries USC FCCCHR approval, which many jurisdictions accept as their sole approval list.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat shutoff valves are included?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eIt is supplied with outside screw and yoke (OS\u0026amp;Y) gate valves on the inlet and outlet. OS\u0026amp;Y gates give the visible open\/shut indication that fire-line and many water-authority specs require.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eIs this listed for fire protection service?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes — it is UL Classified and FM Approved, the listings normally required for a backflow device on a fire sprinkler supply.\u003c\/dd\u003e\n\u003c\/dl\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Double Check\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 4\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInlet Size:\u003c\/strong\u003e 4\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet Size:\u003c\/strong\u003e 4\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Flanged\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBody Material:\u003c\/strong\u003e Cast Iron\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Pressure (psi):\u003c\/strong\u003e 175\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Domestic Water\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackflow Protection:\u003c\/strong\u003e Both\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation:\u003c\/strong\u003e Continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e United States\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1 Year Limited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e LF709-OSY NYC 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e ASSE-1015, CSA-B64, UL, FM, USC, IAPMO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLead-Free:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly Type:\u003c\/strong\u003e Double Check\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazard Protection Level:\u003c\/strong\u003e Low Health Hazard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eASSE Standard:\u003c\/strong\u003e ASSE 1015\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSC FCCCHR Approved:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire Protection Listing:\u003c\/strong\u003e UL Classified;FM Approved\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Testable:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Test Cocks:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShutoff Valves:\u003c\/strong\u003e OSY Gate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlood Sensor (SentryPlus Alert):\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrainer Included:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Gap Fitting Included:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Watts","offers":[{"title":"Default Title","offer_id":54935511466283,"sku":"88007506","price":12532.56,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0277\/3168\/9577\/files\/1447cee0d84465e9a0202ab8f4db75bf840f0d0e_6c7fc55a-ae04-43c3-8226-5b9df18f82e3.jpg?v=1785984284","url":"https:\/\/citysupplygroup.com\/products\/watts-88007506","provider":"City Supply","version":"1.0","type":"link"}